IMU Errors and the Flipper Cable
Last updated
Last updated
The flipper cable runs from the GCU to the roll beam (pic below for reference). It can become easily damaged or pinched and, when damaged, will cause the motors to stop working. You'll know that it's the flipper cable by the IMU error that can be seen in the app. Within the app, on the first page, you'll see WARNINGS to the upper right. Clicking this will show any errors that the gimbal is currently having. Don't fret, this is a simple fix! You can pickup a new cable in our online store, and we have a handy video guide detailing the replacement process.